Surveymeter LUCREST ADP-1111


γ detector ADP-1111 measures Gamma (and X-ray) with high accuracy.
The 2 switches on the grip enable data-saving and time-constant changing, while directing it to the target.
This detector is connectable with TDC-9111.


Specifications

Radiation DetectedGamma (and X-ray)
DetectorNaI(Tl) scintillator
Detector sizeΦ25.4 mm × 25.4 mm
Relative Intrinsic ErrorWithin ±15%
LinearityThe response is within 0.85 to 1.22
(1 in 1μSv/h, IEC 60846-1:2009)
EnergyDose rate: 50keV to 3MeV
(The energy exceeding 3 MeV is compensated as 3 MeV)
Counting rate: 50keV or more
Measurement Range0 to 30.0ks-1, 0 to 1.80M min-1
Background to 30.0 μSv/h, or 30.0 μGy/h
Background to 3.00 mR/h, or 3.00 mrem/h
OthersSwitches to change time constant and
save data, and LED light
WeightApprox. 340 g (excluding cable)
<TDC-9111>
Connectable Detectorsα/β detector, β detector, γ detector.
Radiation types are automatically identified when detector is connected.
DisplayBlack and white LCD (with backlight and touch panel)
Display ModeDetailed, simplified, time-series, scaler, preset list and user settings
Displayed ContentsMeasurement value (digital and bar graph), measurement unit,
radiation type, time, time constant, battery level, peak hold value
and overload, etc.
SoundAlarm, measurement count
AlarmSettings: α, β and γ can be individually set
Display: alarm, sound simultaneously with LED flashing
Alarm ClearAUTO: Automatic clear when the value is under preset
HOLD: Alarming until RESET switch is pressed
Scaler ModePreset time: 1 to 9,999 sec (999,999 counts at max by selecting 0)
Repeat time: 5 times at max
EarphoneEarphone adapter socket for Micro USB is required
Data SavingInstantaneous value at any time or at preset intervals
144,000 data (in case of 100-day measurement at 60-second intervals)
100 folders can be created at max
OutputUSB2.0, Mass storage class
PowerPrimary battery: 8 AA alkaline batteries
Secondary battery: 8 AA NiMH batteries
USB supply (USB2.0)
Battery LifeConnecting ADP-1111
Primary battery: 30 hours or longer (by new batteries at 20 degrees C)
Secondary battery: 12 hours or longer (by full-charged batteries at 20 degrees C)
Environmental requirements in
operation
Temperature : -20 to +50 degrees C
Humidity : 90%RH or less (Non-condensing)
DimensionsApprox. 10 (W) x 19 (D) x 8.5 (H) cm
(excluding handle and protrusions)
WeightApprox. 740g (including batteries, and excluding detector and cable)